Heat recovery 208 230v 460v 575v vrv t series. Heat pump 208 230v 460v 575v vrv aurora.
Daikin Air Conditioner Wiring Diagram Daikin Ac Wiring
Daikin vrv system wiring diagram. Each vrf vrv manufacture may have slightly different vrf system control wiring layouts but they all have maximum outdoor units and indoor units that a control panel can be connected to without the addition of an expansion module or adapter wire 7daikin allows 64 maximum fan coils that you can put on one control panel. Vrf vrv control wiring multiple vrf vrv outdoor units. Installation manuals single zone ductless systems. Water cooled heat pump heat recovery. Heat pump p. This control wiring layout is similar amongst the other vrf manufactures.
Wiring adapter pcb description. Page 30 installation field wiring vrv plus 2 4 7 example of performing coolheat setting of two or more outdoor units in block with coolheat selector for the wiring shown in figure 22 be sure to use 075 125 mm vinyl cords with sheath or cables two core. Vrf vrv simple control wiring for a heat recovery system using single port branch selector boxes. L1 l2 l3 20a 3ph 34 c 4 10 thhn 1 10 cu. The group control adapter pcb facilitates remote start stop control temperature setpoint for remote control groups and contact closure outputs for operation and malfunction status. Bsvq36 60pvju 2 4 combination this bs unit is only for systems for models reyq p.
Note do not throw away any of the accessories until installation is complete. Heat pump and heat recovery pb series. Heat recovery 575v vrv aurora. Water cooled system air conditioner. Three core cables can be used only for the coolheat selector insulated. 1daikin vrv wiring diagram m4nts hp 1 reyq336pbyd remq120pbyd remq96pbyd remq120pbyd q1q2 q1q2 q1q2 l1 l2 l3 21a 3ph 34 c 4 10 thhn 1 10 cu.
It cannot be connected to systems for models reyq m. The daikin vrv system is a multi split type air conditioner for commercial buildings that uses variable refrigerant flow control developed by daikin to provide customers with the ability to maintain individual zone control in each room and floor of a building. English 4 2 3 accessories check the following accessories are included with your unit. Page 47 refrigerant piping intake transmission wiring intake knockout hole ø27 power supply wiring intake knockout hole ø53 drain pipe connection od ø26 anchor point bolt 4 m12 rxysq812tmy1b installer and user reference guide vrv iv s system air conditioner 4p404225 1b 201603. Vrv iv reyq 575v.