Explanations of p h diagram refrigerant. Remote control wiring p1p2 liquid gas vrv 6 20 hp up to 120 hp max6 circuits vrv 6 120 hp single vrv system configuration multiple indoor units with ahu configuration in case of more than 60 hp system connection is multiple vrv system each coil up to 20 hp max combination of 6 120 hp control wiring remote control wiring p1p2 liquid.
Water Cooled Vrv Daikin
Daikin vrv system wiring diagram pdf. Three core cables can be used only for the coolheat selector insulated. Heat pump 208 230v 460v 575v vrv aurora. 1 daikin vrv wiring diagram m4 nts hp 1 reyq336pbyd remq120pbyd remq96pbyd remq120pbyd q1q2 q1q2 q1q2. Vrv 9 260 daikin ffxaq07pvju 8500 6167 20811 la5 1921 a007 30 32x10x12 cdef heatingcooling vrv 1 bs 1 vrv 3 bs 4 btuh btuh. Vrv iv reyq 575v. Heat pump and heat recovery pb series.
Page 30 installation field wiring vrv plus 2 4 7 example of performing coolheat setting of two or more outdoor units in block with coolheat selector for the wiring shown in figure 22 be sure to use 075 125 mm vinyl cords with sheath or cables two core. Number of the indoor units to be connected downstream. It cannot be connected to systems for models reyq m. Water cooled system air conditioner. Daca egvuse09 07c printed in usa. Heat recovery 208 230v 460v 575v vrv t series.
Vrv system schedule. Each vrf vrv manufacture may have slightly different vrf system control wiring layouts but they all have maximum outdoor units and indoor units that a control panel can be connected to without the addition of an expansion module or adapter wire 7daikin allows 64 maximum fan coils that you can put on one control panel. Outdoor units vrv heat recovery reyq8 48p8p9 2 vrv systems outdoor units 1 specifications 9 c ip e nsn r8umu ep 8 tr 4 aoso eoy 8 hdsq vtv y rure vovr 1 1 technical specifications reyq8p9y1b reyq10p8y1b reyq12p9y1b reyq14p8y1b reyq16p8y1b reyq18p9y1b reyq20p9y1b outdoor unit reyq8p9y1b reyq10p8y1b reyq12p9y1b reyq14p8y1b reyq16p8y1b remq8p9y1b remq8p9y1b. This bs unit is only for systems for models reyq p. Vrf vrv control wiring multiple vrf vrv outdoor units. 092007 k akfs americas 2007 vrv systems basic operation guide engi egvuse09 07c engineering data engineering data daikin ac americas inc.
Daca egvuse09 07c basic information 1 vrv systems basic operation guide 1. Heat recovery 575v vrv aurora. Service troubleshooting. Heat pump p. Select the bs unit to fit the total capacity sum of unit s capacity and max. For series of applicable indoor units refer to the catalog or other literature.
Water cooled heat pump heat recovery. Page 47 refrigerant piping intake transmission wiring intake knockout hole ø27 power supply wiring intake knockout hole ø53 drain pipe connection od ø26 anchor point bolt 4 m12 rxysq812tmy1b installer and user reference guide vrv iv s system air conditioner 4p404225 1b 201603.