Diversitech ws 1 wet switch flood detector instructions pdf 813 kb reviews. Dec 03 how to reset float switch.
34 Wet Switch Wiring Diagram Wiring Diagram List
Wet switch ws 1 wiring diagram. Restore power to the system. If an alarm condition exists the homeowner can turn the alarm off with a insilencein. Get expert assistance from our team. Button until service is obtained however a red trouble led will remain lit. Detailed and large wiring diagrams are on the motor and the motor carton and also in the installation and safety instruction sheet. A lit led indicates the wet switch is activated and has turned the unit off.
The double throw relay allows for wiring to interrupt the system and to sound an alarm by others when moisture is detected. Wet switch flood detector. Ws 1 wet switch. Route the cable from the wet switch to cooling control voltage transformer as shown in the wiring diagram. Place wet switch padded side down on the surface to be monitored. Sun 9a 3p mon thu 7a 7p fri 7a 6p sat 9a 3p ct.
Connect black wire from wet switch to same wire on transformer where common was cut. It turns the system off when moisture due to condensate or drain leaks is detected. Call our product specialists at 800 865 5931. It now has a built in test and reset button for easier installation. Wires may be extended as necessary but avoid excess run lengths. One or two drops will cause wet switch to turn off a unit alerting a serviceman to a moisture problem.
The installation instructions provided with the diversitech ws 1 wet switch. Diversitech ws 1 wet switch flood detector double throw relay allows for wiring to interrupt system and to sound an alarm by others when moisture is detected. Wire can be extended if necessary. Connect wiring as shown in the diagrams on page 2. Use with the wet switch sos condensate cop cp 22 all types and all float switches on 24vac control circuits. The wet switch is designed to interrupt the operation of cooling systems.
Thank you for a better wiring diagram then the original in the. Connect green wire from wet switch to common wire that was cut from transformer in step 4. Cut common wire of transformer. Diversitech ws 1 wet switch flood detector the wet switch flood detector is a solid state control designed to help prevent flooding damage to carpets walls furniture ceilings etc. Controlling selected components system components such as compressors electric valves condenser model no. The wiring diagrams are very route the cable from the wet switch.