Typical wiring refer to figures 1 2 3 or 4 refer to the appropriate wiring diagram below and wire the addressable interface module accordingly. Model htrid as well as models htri s and htri r which are both designed to monitor a no or nc dry contact.
Fire Alarms 23
Siemens htri d wiring diagram. Hlim loop isolator module the hlim isolates short circuits on firefinder xls analog loops. Details for ordering notice. The siemens fire safety htri series. By placing devices between hlims during installation a short in the wiring within that group is discon nected from the rest of the loop. Figure 9 security point 1076 wiring connections terminal 5 of the htri s d r must be connected to a known good earth ground for proper operation. Page 17 htri r is a single input module with an independently controllable form c relay.
Siemens htri d intel interface module dual pn. Two 2 34 conduit knockouts one 1 12 conduit opening the inlet sampling tube length is determined by the width of the air duct being protected. 18 awg minimum 14 awg maximum cerberus pyrotronics tri b6m intelligent interface modules shall provide the means of interfacing direct shorting. The htri series modules provide the most. The inlet tube can then be. Htri s r draws 13ma htri d draws 13ma 10.
Ntelligent interface modules are designed to provide the means of interfacing direct shorting devices to the fire alarm control panel facp loop circuit. Modelshtri d dz htri r rz and htri s sz and uscg h. Siemens htri d intel interface module dual pn. Mounting diagram models htri s htri d and htri r mount directly into a 4 inch square 2 ¼ deep box or to a user supplied double gang box. For marine installs product overview. Siemens siemens siemens industryindustryindustry inc.
This marketing data sheet is not intended to be used for system design or installation purposes. Sampling tube selection table. Positive and negative ground fault detected at 25k ohms for terminals 3 and 4. The interface module reports the status of the no or nc contact to the control panel. Pn 315 033744 18 building building building tttececechnologies divisionvisionvision installation operation and maintenance manual firefinder xls control panel. If you are outside of the united states we can also help you contact us before making your payment.
The inlet tube f greater than and nearest to the duct width f should be used see. A 5 inch square off white faceplate is included with each htri series module. The htri d is a dual input. The siemens mode htri series intelligent interface modules are available in three 3 types. Hii have a device with output 4 20 ma and i want to connect it to two analog input module as a redundant can anybody send to me the wiring diagram for connectingthanks in advancekind regards. Housing comes with three 3 wiring entry ports.