According to cummins newage the e000 23412 has a very minor change in the circuitry but they are interchangable with the e000 23410. Will also replace the newer e000 23412.
9ac9 1983 Ford Mustang Alternator Wiring Diagram Free Picture
Mx341 wiring diagram. Mx341 is a two phase sensed automatic voltage regulator and forms part of the excitation system for a brush less generator. A043y699 issue 2 5 ref. Lml se connection diagram. Adjustment of the ufro potentiometer will. Mx automatic voltage regulator avr mx technical specification. Voltage 140 220v ac max 3 phase 3 wire current 3aphase frequency 100 120 hz nominal output voltage max 120v dc current continuous 27 a.
Mx341 trim droop volts stability selection ufro frequency selection indicator led stability k1 k2 power isolation link normally fitted refer to generator wiring diagram for connection details dip exc. Other series mx poles. Please right click on the image and save the picture. 19092018 19092018 5 comments on mx341 wiring diagram. 21 mx341 technical specification. Compatible with newage mx stamford mx e onan.
Mx341 is a two phase sensed automatic voltage regulator and. It has improved motor starting performance and sustained short circuit current. The mx341 is an analogue 2 phase sensing permanent magnet generator pmg powered automatic voltage regulator avr providing isolation from the effects of non linear loads. Refer to alternator wiring diagram for connection details. The mx avr is a two phase sensed automatic voltage regulator and forms part of the excitation system for a brush less generator. Our people also have some more photos associated to stamford generator wiring diagram please see the photo gallery below click one of the.
Sensing input refer to alternator wiring diagram for connection details. Hand trimmer adjust alternator output increase voltage. Mx341 trim droop volts stability selection ufro frequency selection indicator led stability k1 k2 power isolation link normally fitted sensing links standard positions 4p60h z 4p50h z 90kw 90 550kw 550kw dip exc. Trip 550kw 90kw 90 550kw 4p60h z 4p50h z no link 6p50hz 6p60h z sensing links standard positions. Excitation power is derived from a three phase permanent magnet generator pmg to isolate the avr control circuits from the effects of nonlinear loads and to reduce radio frequency interference on the generator terminals. This is the stamford mx341 avr wiring diagram cabg diagram wiring diagram of a photo i get from the stamford generator wiring diagram collection.
Wiring diagram for connection details mx avr outline drawing figure 1. You can save this picture file to your own personal pc. Control function turn potentiometer clockwise to 1 avr volts adjust alternator output increase voltage voltage 2 link. Voltage regulator for newage mx341 cummins onan 305 0846 our vr341 voltage regulator is an exact replacement for stamford newage mx341 series part e000 23410. Trip 6p60h z no link 6p50hz refer to generator wiring diagram for connection details.