Wiring diagram b shows a grx tvi wired from two separate distribution panels that may be different phases or voltages. Wiring diagram b shows a grx tvi wired from two separate distribution panels that may be different phases or voltages.
Grx Pwm Pulse Width Modulation Interface
Lutron grx tvi wiring diagram. L1h1is the hotlive feed to power the lighting load. Wiring diagram o shows a grx tvi wired from one distribution panel with 2 separate feeds. It is the line hot feed that powers the internal circuitry of the grx tvi. Lutron lutron grx tvi homeworksr wallbox power module 1 hwi wpm 6d l2 h2 terminals are tied to each other internally. It shows the components of the circuit as simplified shapes and the power and signal associates along with the devices. You can also look for some pictures that related to wiring diagram by scroll down to collection on below this picture.
Easily monitor control and optimize a lutron control system from any tablet pc or smartphone. If the power requirement of the complete system is less than an. Use the internal terminal block label to see where to land wires. Grx tvi wiring diagram lutron maestro wiring diagram diva wiring diagram wiring diagram grx tvi wiring diagram wiring diagram is a simplified okay pictorial representation of an electrical circuit. Make sure l2 h2 and dl2 dh2 dimmed line dimmed hot are fed from the same breaker that powers the control unit. It shows the components of the circuit as simplified shapes and the capability and signal connections between the devices.
Each feature is designed around what is most important to you how well your building is working. Grx tvi ten volt interface features lutron merlin light wiringrschematics for electronic dimming ballasts powering cmh lamps. Wiring diagram a shows a grx tvi wired from one distribution panel. Use l2h2 100 127v only if your linemains voltage is 100 127 v. Run separate neutrals for load circuit and control circuit no common neutrals. Use l2h2 220 240vce only if your linemains voltage is 220 240 v.
L1h1 is the linehot feed to power the lighting load. Refer to the note on the first page of the grx tvi specification submittal. Lutrons new facility management tool empowers you to manage your building from anywhere. Use the internal terminal block label to see where to land wires. Gp panel 1 distribution panel 3957 l2h2 is the hotlive feed that powers the internal circuitry of the grx tvi. Use the appropriate voltage in the range of 100277 v.
The label shows two separate hotlive terminals l1h1 l2h2. The label shows two separate linehot terminals l1h1 l2h2. Lutron grx tvi wiring diagram lutron ma 600 wiring black brass wiring diagram official lutron grx tvi wiring diagram wiring diagram is a simplified enjoyable pictorial representation of an electrical circuit.