90 133 lmrc 212 two relay wiring diagram pdf 5681kb 90 133 lmrc 212 two relay wiring diagram dxf 55079kb. In a dlm local network with only lmrc 212 or lmrc 212 347 room controllers the room controller with the highest serial number is the master carrying load 1 and load 2.
Georgia Energy Code 2020 Lighting Controls Applied
Lmrc 212 wiring diagram. The lmrc 211 347 is rated for up to 15a. Terminate wiring according to wiring diagram. The low voltage lmrj cables can connect to any dlm device with an open rj45 receptacle. Do not connect different load types to the relay. Total load for lmrc 213 not to exceed 20a. In a dlm local network with only lmrc 222 room controllers the lmrc 222 with the highest serial number is the master carrying load 1 and load 2.
Each relay is rated for up to 20a. For dimming ballasts or drivers connect the 0 10v control wires to the 0 10v terminals that match the load relay output connection. The lmrc 222 has two load outputs. The success of a dlm network installation and the functionality of the segment to this device is followed exactly as depicted in the wiring instructions and diagram. The lmrc 213 communicates to all other dlm devices connected to the dlm local network. All line voltage wiring is 12 awg.
The dimming curve must be set for proper operation. The lmrc 211 is rated for up to 20a. The next highest serial number would have load 3 and load 4 and so forth. Sample connection diagram with class 1 class 2 dimming control wiring 44 112mm 32 83mm 2 50mm load onoffdim buttons red configuration led blue load status leds class 2 dlm local network ports not shown. Controls lmrc eliminating wiring errors wattstopper dlm local network parameters lmrc digital onoff volt dimming room controller with 2 relays and 2. Class 1 0 10v and power wires configuration button class 2 0 10v wiring terminal ports cable tie ring lmrc 112 line voltage.
The next highest serial number would have load 3 and load 4 and so forth. Lmrc 222 75 c copper wire only santa clara ca 8008798585 industrial control equipment 46a9 indoor use only mounting the controller the room controller mounts to a four square deep junction box using the included mounting plate with the hinge pins extending away from the box as shown. Connections shown are for example only. All line voltage wiring is 12 awg. The wattstopper digital lighting management local network dlm. Terminate wiring according to wiring diagram.
Wattstopper lmrc 212 wiring diagram. Lmrc 221 75 c copper wire only santa clara ca 8008798585 industrial control equipment 46a9 indoor use only mounting the controller the room controller mounts to a four square deep junction box using the included mounting plate with the hinge pins extending away from the box as shown. 25082018 25082018 1 comments on wattstopper lmrc 212 wiring diagram. 12 typical wiring diagrams tw drawings provide wiring diagrams for dlm room controllers relays and. Lmrc 212 and the lmrc 212 347 room controllers each have two load relays.