Sample connection diagram with class 1 class 2 dimming control wiring 44 112mm 32 83mm 2 50mm load onoffdim buttons red configuration led blue load status leds class 2 dlm local network ports not shown. Plug dlm local network components together in any configuration using.
Watt Stopper Dimming Wiring Diagram Keju Giant Slotenmaker
Lmrc 211 wiring diagram. Wattstopper lmrc 211 wiring diagram. The low voltage lmrj cables can connect to any dlm device with an open rj45 receptacle. All line voltage wiring is 12 awg. Connections shown are for example only. All line voltage wiring is 12 awg. Connect to single 20a circuit.
For dimming ballasts or drivers connect the 0 10v control wires to the 0 10v terminals that match the load relay output connection. Class 1 0 10v and power wires configuration button class 2 0 10v wiring terminal ports cable tie ring lmrc 112 line voltage. Each relay is rated for up to 20a. Total load for lmrc 211 not to exceed 20a. 90 131 lmrc 211 one relay wiring diagram pdf 5313kb 90 231 lmrc 213 three relay with 0 10v dimming wiring diagram pdf 8616kb case studies. Line voltage room controller deep j box daylight.
The lmrc 211 is rated for up to 20a. Lmrc digital onoff volt dimming room controller with 1 relay and 1. Total load rating mount to 4 x 4 x 2 18 deep electri cal box. Do not connect different load types to the relay. In a dlm local network with only lmrc 212 or lmrc 212 347 room controllers the room controller with the highest serial number is the master carrying load 1 and load 2. Wattstopper lmrc 211 digital room controller dimmer single digital room controller 120277v 20a 1hp class 2 single relay onoff dimmer color.
Lmrc 110 series room controllers include one or two relays to switch a total of 10 amps a high efficiency switching power supply and dual 0 10 volt outputs per relay for control of dimmable loads including compatible led drivers or electronic ballasts. Class 2 0 10 volt control wiring. Depending on outputs used a 4 square extension box may be needed. Terminate wiring according to wiring diagram. Cat 5e cables with rj45 connectors. Lmrc 212 and the lmrc 212 347 room controllers each have two load relays.
The next highest serial number would have load 3 and load 4 and so forth. Lmrc 221 75 c copper wire only santa clara ca 8008798585 industrial control equipment 46a9 indoor use only mounting the controller the room controller mounts to a four square deep junction box using the included mounting plate with the hinge pins extending away from the box as shown. The lmrc 211 communicates to all other dlm devices connected to the dlm local network. The lmrc 211 347 is rated for up to 15a.