The vcma 15uls has 12 gal. The condensate pumps low voltage wire set.
Little Giant Wiring Diagram Little Giant Ec 1 Wiring Diagram
Vcma 15uls wiring diagram. Designed for automatic collection and removal of condensate from air conditioning refrigeration and dehumidification equipment when gravity drainage is not possible or practical. 55 4415 model vcma 15ulst. Vcma 15 115 60 10 60 15 46 m vcma 20 115 60 15 93 20 61 m vcma 20 230 5060 05 75 17 52 m safety instructions before getting started this equipment should be installed and serviced by technically qualified personnel who are familiar with the correct selection and use of appropriate tools equipment and procedures. Vcma 20uls wiring diagram wiring diagram is a simplified good enough pictorial representation of an electrical circuitit shows the components of the circuit as simplified shapes and the facility and signal friends amid the devices. Click here for operation manual. The little giant vcma series features a vertical type pumps with stainless steel motor shaft 12 gallon abs tank and removable 38 od.
This is a simple fix if you find the motor kept turning without water removing from. The checker valve adaptor clogged and caused flood in the basement. A wiring diagram usually gives guidance practically the relative point and union of devices and terminals upon the devices to support in building or servicing. 55 4405 model vcma 15uls 150 hp 115 volt 6 power cord if you are intereted in purchasing a case or more please e mail your inquiry to. The chart identifies the high and low voltage wires. If power cord does not have a plug wiring is as follows.
Little giant vcma 15uls 554405 150hp automatic condensate removal pump includes safety switch that can be connected to shut down the air conditioner condenser or wired to an alarm to warn of possible tank overflow. Connect power cord to line voltage specified on motor and nameplate. This condensate pump is about 5 years old. Step 3 run the condensate pumps low voltage wires into the air handlers electrical connection box. Power cord must be connected to a constant source of power not a fan or other device that runs intermittently. Examine the condensate pumps wiring chart.
Also suitable for high efficiency oil and gas fired condensing furnace and condensing boiler equipment. Condensate pump model vcma 15uls. This vcma 20uls has the ability to collect 12 gal. If the condensate pump has a nc and a no low voltage option choose the nc low voltage position. Little giant vcma series is ideal for collecting detecting and the automatic removal of condensate from air conditioning equipment de humidifiers high efficiency furnaces condensing boilers and other equipment where an automatic drain pump is required. Click here for additional specs.
All wiring must comply with local codes.