Duct smoke detector application diagram warning. It reveals the elements of the circuit as streamlined shapes and also the power and also signal connections between the devices.
Fire Detection And Alarm System Engineering
Sk duct detector wiring diagram. Duct widths from 6 inches to 12 feet can be accommodated. Variety of duct smoke detector wiring diagram. Assortment of duct smoke detector wiring diagram. 14 13 12 10 signature duct smoke detector remote test station rear view 1234 12 3 4 14 13 12 11 2 wire duct smoke detector figure 2. As with our duct smoke detectors all duct smoke detector accessories are ul listed. The duct housing allows for mounting of sk relay addressable relay module.
4detector installation 41verify duct air flow direction and velocity model sk duct detectors are designed to be used in air handling systems hav ing air velocities of 100 to 4000 feet per minute. How to read an electrical diagram lesson 1 duration. System sensor convention 4 wire duct smoke detector d4120 wiring instructions duration. Table 1 on page 3 to determine the inlet tube required for different duct widths. It provides early detection of smoke. Installation diagram wiring diagram wire the remote test station to the duct smoke detector as shown in figure 2.
Wiring for 2 wire duct smoke detector system wiring diagram for 2 wire duct smoke detectors powered from initiating device circuit. Be sure to check engineering specifications to. Ordering information part no. A wiring diagram is a simplified traditional photographic depiction of an electric circuit. It shows the components of the circuit as streamlined shapes as well as the power as well as signal links between the gadgets. The model sk duct air duct smoke detector utilizes photoelectric technology for the detection of smoke.
The panel in turn depending on programming and wiring turns off fans blowers and other devices. Superduct conventional two wire duct smoke detector 1 superduct conventional two wire duct smoke detector pn 3100737 rev 10 06sep05. Duct widths from 6 inches to 12 feet can be accommodated. 4 detector installation 41 verify duct air flow direction and velocity model sk duct detectors are designed to be used in air handling systems hav ing air velocities of 100 to 4000 feet per minute. Superduct duct smoke detectors are not intended as substitutes for open area protection. Description d4120 4 wire photoelectric low flow duct smoke detector accessories d4s 4 wire photoelectric sensor component only etx metal exhaust tube duct width 1ft 03m d4p120 4 wire photoelectric power board component.
A wiring diagram is a simplified traditional pictorial depiction of an electric circuit. 24 v ac 10 15 full w ave rectified unfil tered power ma y be used rts151rts151key optional remote test station magnet test switch alarm led red 4 5 2 1 ra rts ra.