7 siemens cm1n9205en smart infrastructure 2020 03 17. Product and part numbers product description.
Desigo Building Automation System 6 0 Sp Online Safety
Siemens dxr2 wiring diagram. All wiring must conform to nec and local codes and regulations. Use the tool below to quickly find and download one line diagrams. The looped supply 230 v is interrupted when plug 51 54 is disconnected from the device. Siemens a6v11259964en b smart infrastructure unrestricted 2020 01 16. Siemens cm1n9206en smart infrastructure 2020 03 17 features programmable. Page 2 of 7 siemens industry inc.
Siemens cm1n9204en smart infrastructure 2020 03 17 bulk packages 18 pieces type stock number applications inputs outputs dxr2e09 101abp s55376 c165 fan coil radiant ceiling radiator 4 luminaires 2 blinds 1 di 2 ui 3 relays 3 ao dxr2e09t 101abp s55376 c166 4 triac 1 ao 1 relay dxr2e10 101abp s55376 c164 4 triac 3 relays accessories. Page 3 5 siemens industry inc. Siemens cm1n9205en smart infrastructure 2020 03 17 features programmable the dxr2. Wiring diagrams for typical tiastar units tool. Wiring must be sufficiently insulated to the available rated voltage. A6v10549963 installation instructions january 13 2016.
Siemens motor control center wiring diagrams are at your fingertips within seconds. 3333 old milton parkway alpharetta ga 30005 siemens nema control 87 cut sheet1. The wiring must be fixed using cable binders to the tabs on the housing base. Wiring diagrams size 1 4. Compact series the compact build permits mounting directly on the damper shaft and is designed for vav and fpb. Siemens cm1n9207en smart infrastructure 2020 03 17 features programmable.
Dxr2 compact room automation station bacnetip 230 v flat housing 1 di 2 ui 3 do relays 3 ao 010 v n9204 n9206 dxr2e09 101a dxr2m09 101a 1 r1 knx pl link room operator unit with temperature sensor segmented backlit display touchkeys n1602 qmx3p34 1. Insert wiring diagram the replacement is complete. The wiring must be fixed using cable binders to the tabs on the housing base. Low voltage switchgear and other power distribution equipment. Dxr2e12p 102k dxr2e12p ras for ul864 dxr2e12px 102k dxr2e12px ras for ul864 dxr2e10pl 102b compact room automation station and actuator combination bacnetip 24 v 1 di 2 ui 1 ao 4 triac pressure sensor 30 data points. Automation stations provide the infrastructure for system and application specific functions and can be programmed.
Terminal cover break off the cable inlets to insert the cables to the room automation station. Dxr2m11 dxr2m12p dxr2m12px dxr2m18. Room automation stations provide the infrastructure for system and application. Features programmable the dxr2. And plug the terminal block back into the dxr2. Siemens devices legend type of unit data sheet product no.
Sizing and fusing of the wiring depends on the connected load.