Gfci protection is required for all underwater lighting operating over the low voltage contact limit. Is this setup okay.
Wpc2 Wireless Controller For Swimming Pool Peripherals User
Pool light gfci wiring diagram. All ground wires green should be tied to the grounding bar. This diagram illustrates wiring a gfci receptacle and light switch in the same outlet box a common arrangement in a bathroom with limited space. I noticed i was not able to reset the gfci but the pool light and receptacle kept working. I opened the pool sub panel and it seems that whoever wired the gfci might have wired it incorrectly or upside down ie the line and loads wires were at the bottom and load were at the. Gfci can now setreset pool light switch works fine and circuit tester reports correct wiring. 12v pool light wiring diagram trusted wiring diagram online pool light wiring diagram wiring diagram includes many detailed illustrations that display the relationship of assorted products.
In a situation like this it would be best to have a licensed electrician install the necessary gfci protection for the pool light and at the same time take a look at all of the electrical wiring and devices in the area of the pool and then make recommendations about anything that is not up to current electrical code standards. View attachment visio aqualink rs light wiringpdf i found this installation manual of the aqualink rs on line see pages 12. Gfci protection is required for all receptacles that supply power to the pool equipment such as water heaters and pump motors. Wiring a light switch diagram 1. Gfci protection is required for all 120v to 240v single phase pump motors. The neutral and ground wires are spliced together and run to each device in the circuit.
I noticed the wiring layout seemed a little odd so i put a diagram to explain the layout a little better. In this gfci outlet wiring and installation diagram the combo switch outlet spst single way switch and ordinary outlet is connected to the load side of gfci. I used a circuit tester and it reported a hot neutral reverse. The neutrals whites of the pool and spa lights get tied back to the gfci load side neutral. I bought a new smart lock gfci and wired it up correctly. It means all the connected loads to the load terminals of gfci are protected.
I am attaching a diagram of what i think you should have. I have a pool light and a two plugs receptacle connected to a gfci. If more than 1 black and 1 white conductor are in the electrical box also loosen the load side silver and brass terminal screws. Refer to the diagram above about wiring gfci receptacles for additional help. The features and benefits of gfci outlets and receptacles will give you a clear understanding of the importance why these safety devices are required by code to help protect you and your family against accidental electrical shock hazards. The hot source is spliced to the line terminal on the receptacle and to one terminal on the light switch.
How to wire gfci outlets gfci and gfi wiring diagrams. Loosen the silver and brass terminal screws on the line side of the outlet. Wiring a gfci outlet with combo switch outlet receptacle light switch. It includes instructions and diagrams for various varieties of wiring methods as well as other items like lights windows and so on.