All wiring must conform to applicable local codes ordi. It reveals the parts of the circuit as streamlined forms and the power as well as signal links in between the tools.
Intelligent Fire Alarm Control Pane Series Of Fire Alarm
Notifier fcm 1 rel wiring diagram. Notifier slc wiring manual document 51253. The box must have a minimum depth of 218. Compatible notifier system control panels only list available from notifier. It will then enter a 3 second window awaiting a pair of confirmation signals. 16112018 16112018 3 comments on notifier fcm 1 wiring diagram. Notifier nfs manual online.
The fcm 1 rel releasing control module uses a redundant protocol. Variety of notifier fcm 1 wiring diagram. Fmm 1 connect modules to listed compatible notifier control panels only. Frm 1a installation document i56 3502. Connecting a releasing device to a fcm 1 module connecting an. Compatible notifier system control panel list available from noti fier.
Releasing applications c limited energy cable cannot be used to wire a. Dn 6724 040504 page 1 of 4 fcm 1 module see wiring diagram fig. The box must have a minimum depth of 21 8. Notifier fcm 1 wiring diagram. Install contact closure devices per manufacturers installation instructions. 15 to 32 vdc.
Maximum slc current draw. Surface mounted electrical boxes smb500 are available. A wiring diagram is a simplified conventional pictorial representation of an electric circuit. All wiring shown is supervised and power limited. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit. 4675 h x 4275 w x 14 d mounts to a 4 square by 218 deep box specifications for frm 1.
Connecting a releasing device to the fcm 1 rel. Current rating maximum voltage load description application. Ing power limited and non power limited wiring in the same junction box as fcm 1a. Any number of ul listed contact closure devices may be used. Mounting the frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. All wiring must conform to applicable local codes ordi.
32f to 120f 0c to 49c dimensions. The module must be armed with a pair of signals in order to activate. Mounting the fcm 1 mounts directly to 4 square electrical boxes see figure 2a. If no confirmation is received the module will automatically reset. Surface mounted electrical boxes smb500 are available from notifier. Fcm 1a installation document i56 1169.
Maximum slc current draw. 65 ma led on temperature range. Page 5 wiring diagrams this page. For installation instructions see the following documents. 15 to 32 vdc. Notifier nfse manual online.
The fcm 1 rel module must be programmed with the correct releasing type code listed in the nfs 320ec programming manual. If using the on board nacs see circuit requirements for section 474 connecting a releasing device to the control panel on page 44.