Connect modules to listed compatible notifier control panels only. Install contact closure devices per manufacturers installation instructions.
How To Use Electrical Wiring Diagram 1 9 Classification
Frm 1 wiring diagram. 4675 h x 4275 w x 14 d mounts to a 4 square by 218 deep box specifications for frm 1. The frm 1 relay control module is intended for use in intelligent two wire systems where the individual address of each module is selected using the built in rotary switches. Maximum slc current draw. Fmm 101 mini monitor module. Smaller size fits inside devices or junction boxes. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b.
Secure module to electrical box supplied by installer see figure 2a. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams. Page 5 wiring diagrams this page. Variety of notifier fcm 1 wiring diagram. Install module wiring in accordance with the job drawings and appropriate wiring diagrams. When using control modules in.
Relay module wiring diagram. Surface mounted electrical boxes smb500 are available from notifier. 65 ma led on temperature range. 32f to 120f 0c to 49c dimensions. Module polarities are shown in alarm. It reveals the parts of the circuit as streamlined forms and the power as well as signal links in between the tools.
Module mounting with barrier. All wiring must conform to applicable local codes ordi nances and regulations. A78 2611 11 a78 2610 08 specifications normal operating voltage. All wiring shown is supervised and power limited. All wiring shown is supervised and power limited. It allows a compatible control panel to switch discrete contacts by code command.
Removing rotary switch stop. Removing general description rotary switch stop. Transmits the status of one zone of 2 wire detectors to the fire alarm control panel. Typical notification appliance circuit configuration nfpa style y. Maximum slc current draw. Fmm 1 connect modules to listed compatible notifier control panels only.
65 ma led on. The frm 1a provides two form c dry contacts that switch together. Page 1 figure 1. 15 to 32 vdc. Operation each fcm 1a or frm 1a uses one of 159 possible module addresses on a slc loop 99 on clip loops. Typical fault tolerant notification appliance circuit configuration nfpa style z.
The fcm 1a is configured for a single class b style y or class a style z notification appliance circuit. A wiring diagram is a simplified conventional pictorial representation of an electric circuit. Fzm 1 zone interface monitor module. Class b supervised wiring to the monitored device. Any number of ul listed contact closure devices may be used. Set the address on the module per job drawings.
The box must have a minimum depth of 21 8. 15 to 32 vdc maximum current draw. The frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. 15 to 32 vdc. Class a supervised wiring to the monitored device.