5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit. Some control panels have relay built in and do not require external wiring.
Bms System Building Management System Basic Tutorials For
Fire alarm control module wiring diagram. Box and the control module must be placed into the barrier and at tached to the junction box figure 2a. Install module wiring in accordance with the job drawings and appropriate wiring diagrams figures 3 10. Refer to notifier manual. Fire alarm security access control cctv published by edwards systems technology in conjunction with paige electric co lp. Addressability al lows the fcm to be activated either manually or through. Break wire run to provide supervision.
An automatic fire alarm systemtypically made up of smoke detectors heat detectors manual pull stations audible warning. The information shown for each control panel includes wiring diagrams and circuit tables. The circuit type is designated with a letter a z. It shows the components of the circuit as simplified shapes and the capacity and signal associates together with the devices. Siga rel 69 isolator module. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b.
Is recommended 24 vdc circuit 3 4. Fire alarm control module wiring diagram wiring diagram is a simplified customary pictorial representation of an electrical circuit. Siga im 70 audio. To next control module or end of line relay. An esz is a discrete area of a building bounded by smoke or fire barriers in which occupants are intended to relocate or evacuate. Fire alarm system is the combination of different components such as smoke detector heat detector carbon monoxide detector multi sensor detector call points sounders bells relay module repeater annunciator fire control panel and other related and optional security devices designed for fire alarm control system.
Fcm 1 module see wiring diagram fig. 2 firelite slc wiring manual pn 51309r2 3192019 fire alarm emergency communication system limitations while a life safety system may lower insurance rates it is not a substitute for life and property insurance. One relay required for each circuit. Module polarities are shown in alarm connect modules to listed compatible 32 vdc max. Level 0 means no survivability is required wiring within the esz level 1 3 indicate that attack by fire shall not impair the control and operation of notification appliances outside the esz.