Compatible notifier system control panels only list available from notifier. Install contact closure devices per manufacturers installation instructions.
Notifier Fmm 1 Installation Manual
Notifier mmx 1 wiring diagram. Releasing applications c limited energy cable cannot be used to wire a. This module is intend ed for power limited wiring only. Mmx 1e sem screws with clamping plates for ease of wiring mmx 1e lpcb and vds approved installation the mmx 1e mounts in the notifier multi mount enclosure or an smb500. The fmm 1a can be used to replace mmx 1a modules in existing systems. All wiring shown is supervised and power limited. Fzm 1 applications use the fzm 1 to monitor a zone of two wire smoke detectors.
The mmx 102e mounts in a standard single gang electrical knock. Surface mounted electrical boxes smb500 are available. Connecting a releasing device to a fcm 1 module connecting an. Fmm 1a applications use to monitor a zone of four wire smoke detectors manual fire alarm pull stations waterflow devices or other normally open dry contact alarm activation devices. The monitored circuit may be wired as an nfpa style b class b or style d class a ini tiating device circuit. Mounting the fcm 1 mounts directly to 4 square electrical boxes see figure 2a.
A 39 k ohm end of line resistor pro. Notifier nfs manual online. Fzm 1 has a panel controlled led indicator and can be used to replace mmx 2 modules in existing systems. Notifier fcm 1 wiring diagram. The box must have a minimum depth of 218. The smb500 may then be installed in a 19 rack assembly using notifier 19 rack mounting adapters.
When using control modules in nonpower limited applica. All wiring must conform to applicable local codes ordi. Surface mounted electrical boxes smb500 are available from notifier. Monitor modules model numbers include the fmm 1 fmm 101 fzm 1 and fdm 1. Notifier nfse manual online. Mounting mmx 1a cmx 2a and iso x devices mmx 1a cmx 2a and iso x modules mount directly to 4 inch square electri cal boxes as shown in figure 2a.
All wiring must conform to applicable local codes ordi. May also be used to monitor normally open supervisory devices with special. The box must have a minimum depth of 218. Set the address on the module per job drawings. Page 5 wiring diagrams this page. Compatible notifier system control panel list available from noti fier.
All wiring must conform to applicable local codes ordinances and regulations. Install module wiring in accordance with the job draw ings and appropriate wiring diagrams. Monitor modules supervise a circuit of dry contact input devices such as conventional heat detectors and pull stations or monitor and power a circuit of two wire smoke detectors. Any number of ul listed contact closure devices may be used. Fmm 1 connect modules to listed compatible notifier control panels only. Mounting the frm 1 mounts directly to 4 square electrical boxes see fig ure 2a.
Connecting a releasing device to the fcm 1 rel. 16112018 16112018 3 comments on notifier fcm 1 wiring diagram. The box must have a minimum depth of 21 8. All wiring must conform to applicable local codes ordinances and regulations. Notifiers offers a variety of intelligent monitor modules for diverse applications.