I 42 em a iota battery backup tbts series ac 10w 42w rapid start 4 pin compact lamp w damp location ballast kendall electric inc. When the i 42 em a is installed on the same branch circuit refer to illustration 2 figures a and b for input wiring.
I42j Ac I42j Ac
I 42 em a tbts series ac wiring diagram. Therefore when used with switched fixtures the i 42 em r input must be wired ahead of the switch. Bal650c 4 emergency ballast sign 94 x 24 4 pin cfl 13 42w same as iota i 42 em a. Therefore when used with switched fixtures the i 42 em r j input must be wired ahead of the switch. Iota i 42 em a tbts series ac emergency lighting equipment 120 277v use for 1 10w 42w or 2 10w 18w 4 pin compact fluorescent lamp 36v battery 10 out of 5 stars 1. The i 420 em b requires an unswitched ac. I 42 em a iota battery backup tbts series ac 10w 42w rapid start 4 pin compact lamp w damp location ballast kendall electric inc.
When installed on separate br anch circuits ref er to illustration 1 figures c and d f or input wiring. Iota emergency ballast wiring diagram 37 wiring diagram images. Refer to illustration 3 for switched and unswitched fixture wiring diagrams. When installed on separate branch circuits refer to illustration 2 figures c and d for input wiring. Power source of either 120 or 277 volts. Iota i 42 em j emergency backup battery wiring diagram author.
Operates most 10w 42w 4 pin rapid start cfl lamps and 18 36w long compacts 120277v created date. Power source of either 120 or 277 volts. The i 42 em r requires an unswitched ac. It is designed to operate 1 or 2 10 to 42 watt 4 pin rapid start compact twin triple quad tube 2d and straight or a single 18 to 36 watt long compact lamp. Refer to illustration 2 for witched and unswitched fixture wiring diagramss cer to the wiring diagrams on the back page for the proper wiring. Power source of either 120 or 277 volts.
Power source of either 120 or 277 volts. Refer to illustration 1 for switched and unswitched fixture wiring diagrams. Refer to illustration 1 for switched and unswitched fixture wiring diagrams. Refer to the wiring diagrams on the back page for the proper wiring. The i 42 em r j requires an unswitched ac. Therefore when used witched fixtures the with s i 420 em a input must be wired ahead of the switch.
Refer to the wiring diagrams on the back page for the proper wiring. Refer to the wiring diagrams on the back page for the proper wiring. The i 420 em a requires an unswitched ac. Iota emergency ballast wiring diagram 37 wiring diagram imagesiota iem j installation instructionsiota iem r j. Therefore when used with switched fixtures the i 420 em b input must be wired ahead of the switch. Iota i 42 em j emergency backup battery 90 min.
The iota i 42 em a emergency backup battery provides emergency operation for 90 minutes. I 42 em a tbts insure wiring is in accordance with the national electrical code and local regulations.