24 vdc capacity outputs cabinet size 1 4 4 8 8 8 12x9x4 14x14x4 14x14x4 15x18x6 15x18x6 15x18x6 bps 24 1 bps 24 2 bps 24 3 bps 24 4 bps 24 6 bps 24 10 1 amp 2 amp 3 amp 4 amp 6 amp 10 amp. Ed 40005000 m94 x dk11 x bps 24 1 pair doors.
R3c R3 Controller User Manual Manual R2 Pdf Xmark
Bps 12 24 1 wiring diagram. Safe for use with readers electric strikes and maglocks these units interface to fire alarm systems and provide battery backup. The bps 1224 1 is ul class 2 listed. Ed40005000 x m94 x 6900 powermatic x mag x dk 11 x 1 wall plates interior. Bps 12 1 and bps 24 1 operation and installation instructions. Time period reset units and external alarm devices have been connected correctly according to wiring diagram shows text 1 after a short intro procedure. The bps linear power supply delivers more current than psps and all bps models are ul class 2 listed allowing for wire runs without the use of conduit from power supply to door.
Supplies 1 full amp continuous current output even while charging back up batteries. Batteries are an option. The bps series of power supplies delivers linear technology recommended by most manufacturers of sensitive electronic access control and security components. Bpsm 24 4 6 and 10 operation and installation instructions. Wiring diagrams and instructions. Make sure power supply.
Ed40005000 x m94 x dk11 x bps 24 1. The bps 1224 1 is ul class 2 listed allowing for wire runs without the use of conduit from power supply to door. Black stripe black red red whtred red white black whtblu blue orange green. Bpsm 12 6 9 and 15. Note that a special version of the bps 1224 1 operates on 220 vac input. Local building department to make sure you are complying with applicable wiring codes before installing these units.
Bps 1 amp c no nc rex dk 12 magnalock nc 1 no 2 com 1 com 2 pb3er fail safe wiring with rex. Wiring for bps 12 1 and bps 24 1. Ccm 1 ccm 1n installation and operating. Bps 24 2 3 4 6 and 10 operation and installation instructions. The power supply can be used with or without them. 30 documents similar to martechnicltd bnwas u was usermanual 1 kenr uploaded by.
Bpss 10 bpss 20 installation and operating instructions. Dual output field selectable 12 or 24vdc via clearly marked toggle switch. Battery charging capability the bps 12 1 or bps 24 1 power supply incorporates a battery charging circuit appropriate for standby rated sealed l ead acid or gel cell batteries. A battery pack of the appropriate voltage see. Discontinued product literature. For c ul listed applications the unit shall be installed in accordance with part 1 of the canadian electrical code.
Connect the pushbutton com 2 to the power supply positive then connect the no 2 of the pushbutton to the keypad rex input. Securitron bps 24 2 power supply 24vdc 2amp recommended where an interface with a fire alarm system or battery backup is needed. Bps 12 3 45 6 9 and 15.